The truth about data center water use
How much water do data centers actually use? Here are the facts — and the problems.

Across the nation, the tech industry is rushing to build new data centers.

In the U.S., there are already more than 3,000 of these large warehouses full of computer systems, which are increasingly used to provide computing power to artificial intelligence (AI). More than 1,500 more are in the works.

The AI these facilities power has real potential to accelerate medical breakthroughs or better identify pollution hotspots. But data centers are already causing major problems, from astronomical energy use to loud noise around the clock.

One of the most misunderstood impacts of data centers is their water use. Let’s dive in and get to the bottom of how and why data centers use water—and how much they actually use.

Why do data centers use water?
Because data centers’ computer servers run nonstop, they generate lots of heat. But in order to continue running, they have to stay cool.

Data centers keep chips cool in a range of ways. Some use enormous air conditioning systems that cool the air in server rooms. Others use more specialized cooling tech such as, for instance, immersing servers in cooling liquid.

But all of the most widely used cooling strategies require some amount of water.

You may be wondering: How much water, and where does it come from?

The second part of that question has a straightforward answer. In 2025, an estimated 97% of data centers’ on-site water needs came from municipal water systems, just like other businesses, homes or facilities in the area.

In some cases, data centers also source their water from wastewater or directly from surface water or groundwater. In one such instance, a data center in California sued for access to 287 million gallons of water each year from the Colorado River. Because one fifth of U.S. data centers are located in areas where water is scarce—and because, as of September 2026, 43 states are experiencing at least moderate drought—that kind of direct water use can have dire consequences.

But just how much water do these facilities actually use?

The truth is that it varies widely, depending on which kind of cooling system a data center uses.

How do data centers cool down — and how does it affect their water use?
Most data centers use an air cooling method called evaporative cooling. In this setup, outside air is cooled using water that absorbs the air’s heat as it evaporates. The cool air is then pumped into the server room to cool the computer chips.

Because this method requires a constant flow of water to evaporate, its water footprint can be enormous. Some large data centers can use 5 million gallons of water per day, or as much as a small city of 50,000 people. While water demand fluctuates as temperatures change throughout the day and year, and can also vary slightly depending on the quality of the water used, the result of this demand is that, each year, billions of gallons of water go toward data centers across the country.

Around 80% of the water drawn by data centers evaporates during the cooling process. But the rest is discharged to nearby wastewater treatment plants, where, after treatment, it can reenter local water supply. This may sound promising; but, in some cases, the massive amounts of water discharged from data centers can overwhelm wastewater treatment facilities that don’t have the capacity to handle such large quantities.

Other cooling strategies use less water. Liquid cooling technologies use liquid to cool computer servers directly, rather than pumping cool air over them, which doesn’t require a constant stream of water to evaporate.

In this setup, water, often mixed with glycol and a cocktail of other chemicals designed to stop microbes, prevent rust, and transfer heat more efficiently, circulates through the system again and again. Each time, it’s cooled down before being applied to computer chips. This circulation is why you might hear these systems referred to as “closed-loop.”

Closed-loop systems have the potential to dramatically reduce a data center’s water use. But they’re not without significant trade-offs.

For one thing, in these systems, the chemicals used in the cooling liquid become more concentrated as they circulate over and over again, and eventually far exceed safe limits. To handle that buildup, small amounts of contaminated liquid are discharged from the system. From there, that toxic liquid, if inadequately treated, can affect local waterways.

Plus, because the liquid in these systems has to be cooled down each time it circulates, closed-loop cooling systems consume more energy than evaporative cooling ones. In other words, there’s a trade-off between using more power and using more water. And while outsized water use is a major risk of data centers, enormous power consumption and the pollution it may cause is also a severe problem.

Aerial drone view of Microsoft’s Fairwater AI data center campus under construction in Racine County.
cflaten/Shutterstock | Shutterstock.com
The hidden water use of closed-loop systems
Closed-loop cooling systems also come with a behind-the-scenes water cost. That’s because power generation facilities themselves use significant amounts of water.

In the U.S., electricity generation uses tens of trillions of gallons of water every year. At fossil fuel power plants, the formula for electricity generation is simple: burn fuel to boil water, then use the steam to spin a generator. While some of the steam is captured and condensed back to water to be reused, much of it evaporates, requiring more to take its place.

It’s important to note that, compared to fossil fuel plants, renewable solar or wind energy requires hardly any water. Yet despite this incentive to turn toward renewables, the data center rush is driving a surge in fossil fuel plant construction.

In other words, even closed-loop systems don’t solve data centers’ water problem. They move it behind the scenes.

Are there better solutions to the data center water problem?
Solving this problem is an ongoing area of technical research. Unfortunately, many of the solutions currently proposed present a whole new set of dangers.

One option that’s gaining traction is to use toxic PFAS to facilitate new cooling options. PFAS, also known as “forever chemicals,” have been linked to a host of harmful health effects, from increased risk of certain cancers to reproductive harm. Introducing it into data centers and producing even more at a massive scale is not a wise path forward.

Another option on the frontier of innovation is using “supercritical carbon dioxide” – which puts CO2 under immense pressure, allowing it to act as a liquid – for cooling purposes. This technology is in its early stages, and should be explored with caution, though it is potentially capable of using sequestered carbon dioxide, which could help keep the planet cool.

Yet another possibility would be to use seawater for cooling, but this approach may threaten important marine ecosystems.